Quality Analysis

Filament Diameter Log

Diameter consistency analysis per spool — tune puller speed and motor RPM

Mean Diameter

1.7514 mm

+0.0014mm from target 1.750

Std Deviation σ

±0.0118 mm

Excellent — σ < 0.015 threshold

Process Cpk

1.42

Capable — Cpk ≥ 1.33 target

% In-Spec

96.7%

87 / 90 samples within ±0.05mm

Min Diameter

1.718 mm

At 12.4m — puller surge

Max Diameter

1.786 mm

At 3.2m — startup overshoot

Diameter vs Spool Position — Run #046 Black PLA

90 samples · 1 sample/meter · tolerance band ±0.050mm shown in green

Actual Ø
10-pt rolling avg
Tolerance band

Sample Log

90 samples · 28 out-of-spec · 1 sample per meter

#TimestampPositionMeasured ØDeviation10-pt AvgStatus
00110:14:000.0 m1.7481 mm-0.00191.7481 mm
In spec
00210:16:001.0 m1.7277 mm-0.02231.7379 mm
In spec
00310:18:002.0 m1.6968 mm-0.05321.7242 mm
Out of spec
00410:20:003.0 m1.6900 mm-0.06001.7157 mm
Out of spec
00510:22:004.0 m1.6900 mm-0.06001.7105 mm
Out of spec
00610:24:005.0 m1.6948 mm-0.05521.7079 mm
Out of spec
00710:26:006.0 m1.6914 mm-0.05861.7055 mm
Out of spec
00810:28:007.0 m1.7092 mm-0.04081.7060 mm
In spec
00910:30:008.0 m1.7289 mm-0.02111.7085 mm
In spec
01010:32:009.0 m1.7442 mm-0.00581.7121 mm
In spec
01110:34:0010.0 m1.7470 mm-0.00301.7120 mm
In spec
01210:36:0011.0 m1.7398 mm-0.01021.7132 mm
In spec
01310:38:0012.0 m1.7002 mm-0.04981.7136 mm
In spec
01410:40:0013.0 m1.6962 mm-0.05381.7142 mm
Out of spec
01510:42:0014.0 m1.6947 mm-0.05531.7146 mm
Out of spec
90 samples